ELISA Kit for Metallothionein 1 (MT1)
MT1A; MT1S; MTC
- UOM 96T
- FOB US$ 466.00 US$ 665.00 US$ 2,993.00 US$ 5,653.00 US$ 46,550.00
- Quantity
Overview
Properties
- Product No.SEB119Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- ApplicationsEnzyme-linked immunosorbent assay for Antigen Detection.
Research use only - DownloadInstruction Manual
- CategorySignal transductionTumor immunity
Sign into your account
Share a new citation as an author
Upload your experimental result
Review

Contact us
Please fill in the blank.
Recovery
Matrices listed below were spiked with certain level of recombinant Metallothionein 1 (MT1) and the recovery rates were calculated by comparing the measured value to the expected amount of Metallothionein 1 (MT1) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 82-94 | 86 |
EDTA plasma(n=5) | 86-101 | 90 |
heparin plasma(n=5) | 99-105 | 102 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Metallothionein 1 (MT1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Metallothionein 1 (MT1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Metallothionein 1 (MT1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 80-101% | 85-98% | 88-101% | 94-101% |
EDTA plasma(n=5) | 86-98% | 83-102% | 79-91% | 92-105% |
heparin plasma(n=5) | 86-95% | 79-94% | 87-97% | 78-103% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Metallothionein 1 (MT1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Metallothionein 1 (MT1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Metallothionein 1 (MT1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Metallothionein 1 (MT1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Giveaways
Increment services
-
Single-component Reagents of Assay Kit
-
Lysis Buffer Specific for ELISA / CLIA
-
Quality Control of Kit
-
ELISA Kit Customized Service
-
Disease Model Customized Service
-
Serums Customized Service
-
TGFB1 Activation Reagent
-
Real Time PCR Experimental Service
-
Streptavidin
-
Fast blue Protein Stain solution
-
Single-component Reagents of FLIA Kit
-
Streptavidin-Agarose Beads
Citations
- Modulated expression of genes associated with NO signal transduction contributes to the cholesterol-lowering effect of electro-acupunctureSpringerLink: c1v4234150886817
- Evaluation of serum metallothionein-1, selenium, zinc, and copper in Ghanaian type 2 diabetes mellitus patientsSpringer: Source
- Peculiarities of antioxidant system and iron metabolism in organism during development of tumor resistance to cisplatinPubmed:25265354
- Neuroprotective effects of levetiracetam target xCT in astrocytes in parkinsonian mice.Pubmed:26485447
- Evaluation of hepatorenal impairments in Wistar rats coexposed to low-dose lead, cadmium and manganese: insights into oxidative stress mechanismpubmed:27599793
- Dyslipdemia induced by chronic low dose co-exposure to lead, cadmium and manganese in rats: the role of oxidative stresspubmed:28654832
- Metallothionein‐1 suppresses rheumatoid arthritis pathogenesis by shifting the Th17/Treg balancePubmed:30055006
- Metallothionein-1 is associated with osteoarthritis disease activity and suppresses proinflammatory cytokines production in synovial cellsPubmed: 31465913
- Influence of cadmium on blood and hair trace elements and biochemical markers
Recommend products
ELISA Kit for MT1M$700, 96T
ELISA Kit for MT1M$700, 96T
ELISA Kit for MT1E$700, 96T
ELISA Kit for DMT1$700, 96T
ELISA Kit for PRMT1$700, 96T
ELISA Kit for SHMT1$700, 96T
ELISA Kit for DNMT1$700, 96T
ELISA Kit for PCMT1$770, 96T