ELISA Kit for X-Ray Repair Cross Complementing 2 (XRCC2)

DNA repair protein XRCC2

Specificity of the ELISA Kit for X-Ray Repair Cross Complementing 2 (XRCC2)

This assay has high sensitivity and excellent specificity for detection of X-Ray Repair Cross Complementing 2 (XRCC2).
No significant cross-reactivity or interference between X-Ray Repair Cross Complementing 2 (XRCC2) and analogues was observed.

Recovery of the ELISA Kit for X-Ray Repair Cross Complementing 2 (XRCC2)

Matrices listed below were spiked with certain level of recombinant X-Ray Repair Cross Complementing 2 (XRCC2) and the recovery rates were calculated by comparing the measured value to the expected amount of X-Ray Repair Cross Complementing 2 (XRCC2) in samples.

Matrix Recovery range (%) Average(%)
80-102 95

Precision of the ELISA Kit for X-Ray Repair Cross Complementing 2 (XRCC2)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level X-Ray Repair Cross Complementing 2 (XRCC2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level X-Ray Repair Cross Complementing 2 (XRCC2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for X-Ray Repair Cross Complementing 2 (XRCC2)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of X-Ray Repair Cross Complementing 2 (XRCC2) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
90-103% 88-95% 92-102% 83-97%

Stability of the ELISA Kit for X-Ray Repair Cross Complementing 2 (XRCC2)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for X-Ray Repair Cross Complementing 2 (XRCC2)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for X-Ray Repair Cross Complementing 2 (XRCC2)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to X-Ray Repair Cross Complementing 2 (XRCC2). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to X-Ray Repair Cross Complementing 2 (XRCC2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain X-Ray Repair Cross Complementing 2 (XRCC2), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of X-Ray Repair Cross Complementing 2 (XRCC2) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPG147Hu01 Recombinant X-Ray Repair Cross Complementing 2 (XRCC2) Positive Control; Immunogen; SDS-PAGE; WB.
PAG147Hu01 Polyclonal Antibody to X-Ray Repair Cross Complementing 2 (XRCC2) WB; IHC; ICC; IP.
MAG147Hu21 Monoclonal Antibody to X-Ray Repair Cross Complementing 2 (XRCC2) WB; IHC; ICC; IP.
SEG147Hu ELISA Kit for X-Ray Repair Cross Complementing 2 (XRCC2) Enzyme-linked immunosorbent assay for Antigen Detection.
LMG147Hu Multiplex Assay Kit for X-Ray Repair Cross Complementing 2 (XRCC2) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK